PXI-5610: √ — I/Q Modulator. 3. com | NI PXIe-5672 Getting Started Guide Artisan Technology Group - Quality Instrumentation. vi Calibration Executive:. 7 GHz Upconverter in a 2-slot, 3U PXI module. NATIONAL INSTRUMENTS PXI-1042 W/ ni pxi-8196, NI-PXI-5610, NI PXI-5421, PXI-808. When I use the devices as vector signal generator I am no longer able to access the divided sample clock. 2. NI PXI-5670/5671 Specifications 12 ni. com Noise Density Noise Floor at 2 GHz Vector modulation bandwidth flatness. 7 GHz RF vector signal generator (VSG). NI PXI-5671 Getting Started Guide (this document) 8. Pages 10. 5 Readme. Model. I have already created the vi's used to transmit and receive the bursts and now I need to set up the timing between them. The NI PXI-5610 RF upconverter is an IF to RF upconverter. The PXIe‑5442 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms, standard functions including sine, square, triangle, and ramp, as well as signals that require onboard signal processing. The specifications document for your device is installed with the. What are the output damage levels of the PXI 5610? Thanks, BCEMy PXI 1042Q chassis has. Page 8: Verifying Voltage Measurement And Output2. This software installation provides support for customers using RF signal generator or vector signal transceiver hardware, as specified in the Supported Hardware section. 8 x 5. but nothing helped. We had a sample RF front end in NI PXI. 5 x 1. 11 Specifications apply only to E-revision and later PXI-5441 devices (National Instruments part number 191789E-0x) 12 Above 50 MHz, the response is the image response. 8, 1. The NI 5670 ships with the NI-RFSG instrument driver, which you use to program the device. PXI & VXI Boards & Modules; National Instruments Ni Pxi-5610 2. Perspectives. Power on the computer and reset the MAX database. NI PXI-5610 RF Upconverter Module 2. I got the downconverted signal but the center frequency signal is 10 MHz which i expect 20 MHz. The NI VSGs that utilize an arb and the PXI-5610 upconverter (PXI-5670, PXI-5671 and PXI-5672) have two different clocking modes for the sample clock: Divide Down and High Resolution. 2D Dimensional Drawings. 7 GHz, PXI RF Signal Upconverter National Instruments PXI-5610 PXI RF Signal UpconverterThe NI PXI-5610 (Part Number: 778737-01) is a 2. . I installed all the driver coming with these modules, but the only folder I can find in the instr. NI PXI-5610 June 2012 Contact: 866-275-6964 373780A-01 support@ni. They have been acquired and sub-divided in m = 10 slots. Perspectives showcases how NI sees what’s next in the world of test and technology. As far as the PXI-5610, there is a know issue simulating this device so you won’t be able to simulated it. This document explains how to install, configure, and test the NI PXI-5670 (NI 5670). 5)的bug显示:当使用PXI-5670和PXI-5671发生频率低于2. PXI Peripheral Slots (PXI only) 4. Driver Software DVD 7. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. RTC transfers the triggers to FPGA. I found and executed the Self Test Internal vi from the 5th post of this NI PXI forum thread The National Instruments PXI-5610 is a 2. NI-VISA. 1 in. This software is intended to solve errors code 12 and/or 31 showing in the device manager of windows. 7 GHz RF vector signal generator (VSG). The specifications document for your device is installed with the driver software. The PXI-5610 and the PXI-5421 work together to provide vector signal generation from 250 kHz to 2. Log in Join. It provides excellent integration with modular function generators for RF generation applications. PXI-5670 September 2017 Notice: This document is subject to change without notice. The IF input must be centered between 15-35 MHz. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. AM Modulation with PXIe 5641R. . I have program my PXI 5610 to transmit a sine wave to my PXI 5600. Two Semi-Flexible SMA (m)-to-SMB Cables, Part Number 190846B-01 4. View and Download National Instruments PXIe-5672 getting started manual online. Using a LabVIEW application on a PC, you can readily develop signals---including those with simulated impairments---for high-speed communications systems. 125M * 4 * 8 = 100M as shown. NATIONAL INSTRUMENT 184384-03 NSFP 18438403. PXI-5610. Product. The NI 5671 comprises the following devices: • NI PXI-5610 (NI 5610) RF. 1862. National Instruments NI PXI-5620 Card. This PXI module must be used in a suitable chassis. 0 積分 第 1 條訊息(共 2 條) 3,885 檢視You can request repair, RMA, schedule calibration, or get technical support. SPONSORED. 7 GHz Upconverter This National Instruments PXI-5610 2. The NI 5670 is a modular 2. 2. Doc Preview. The specifications document for your device is installed with the driver software. 73 GHz PXI Express Controller 4GB RAM 200GB. The RFSG PXI-5670 consisted of an arbitrary waveform generator PXI-5421 and an RF up- converter PXI 5610. 3 GHz PXI RF Analog Signal Generator —The PXI‑5651 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. 1 and I have the latest drivers instaled on my pc, the probem is that the calibration doesn't start and it gives this error: "Open VI Reference in cex_Instr_RFSigGen_Init. 3 to calibrate some PXI-5610 cards. Hello, We have an NI PXIe-1065 chassis with a -PXI 5610 and PXI 5442-AWG together (VSG) and -PXI 5600 and PXI 5142-Digitizer together (VSA). 2. The NI PXI-5610 is a 2. Manuals. Design and Prototype. Starting at $893. . 0 KudosThe PXI-5670 consists of two components, the NI PXI-5610 2. The respective commands are generated, Manchester encoded, BFSK modulated, FM modulated, digital up converted and transferred to RF up conversion module (PXI-5610) through I/O interface of. Find many great new & used options and get the best deals for National Instruments Ni Pxi-5610 2. Hello Ryan, As noted in this post, the PXI-5610 is part of the PXI-567x series RFSG devices and, as such, is documented in the "NI PXI-567X Specification" here and. 2. Some of these signal processing operations include FIR and CIC interpolation filters, digtal prefilter gain. The NI PXI-5610 is a 2. 8. PXIe-5672 test equipment pdf manual download. 7 GHz RF Vector Signal Generators. Pxi-5421 AWG(Arbitrary Waveform Generator) Pxi- 5620 Frequency Digitizer . 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。National Instruments NI PXI-5610 2. The specifications document for your device is installed with the driver software. 7 GHz Upconverter. I installed all the driver coming with these modules, but the only folder I can find in the instr. When I first ran the vi, nothing came up. NI 54xx NI 54xx refers to the AWG module included with the NI 5610 upconverter module to make up the NI 567x. National Instruments NI PXI-5610 2. Letter of Volatility PXI-5671 September 2017 Notice: This document is subject to change. Because PXI Express is compatible with all existing PXI modules, engineers also can use the new NI PXIe-5442 module with the NI PXI-5610 2. 7 GHz RF upconverter, the NI PXI-5421 16-bit arbitrary waveform generator and the NI Modulation. This is a hybrid-slot-compatible PXI module that can be used in both PXI Express hybrid slots and standard PXI slots. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 7 GHz PXI RF Signal Upconverter —The PXI-5610 frequency-translates IF input signals to the desired RF frequency. 7 GHz RF Vector Signal Generators This document lists specifications for the NI PXI-5670/5671 (NI 5670/5671) RF vector signal generators. PXI-8423 NI module, NI, PXI-8423 NI module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. 본 페이지는 PXI-5610 의 치수도면을 제공합니다. PXI Peripheral Slots (PXI only) 4. PXI-5610 (latest calibration is in (3/18/2005) ; NI-driver (14/02/2013) PXI-5421 NI-driver 15/07/2010. The PXI-5610 RF Upconverter is PXI1Slot5 inside the MAX and the PXIe-5442 AWG is PXI1Slot7. Member. National Instruments PXIe-5442 PXI Waveform Generator. This documents provides information on calibration service levels available for NI Products. Pxi-5421 AWG(Arbitrary Waveform Generator) Pxi- 5620 Frequency Digitizer . Please note: according to NI 5610 Calibration Procedure manual,the NI 5610 upconverter module must be cooled to 23 ±5 °C before the adjustment stage of the calibration process,and this may take up to one hour. 01-04-2012 01:37 PM. It provides excellent integration with modular function generators for RF generation applications. 7 GHz RF Upconverter 130db Gain at the best online prices at eBay! Free shipping for many products!PXI. NI PXI-5441 AWG Module 3. The NI PXI-5610 features a wide real-time bandwidth and a highly stable time base, accurate to within ±50 ppb. Software. PRT STP IGS Product Support Resources. Select the chassis in the leftmost pane, then click the Update Firmware button in the right pane. 00. Part Number: 186055F-01, 778283-01. These paremeters are validated in manufacturing production tests and CalExec checks and adjusts gain. Overview. I also have been able to drive the output to +27 dBm in a bursted application without errors. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 7 GHz RF vector signal generator (VSG). vi ? please tell me y?I'm using PXIe-1065 chassis with PXIe-8133 controller and some other modules (PXI-5600, PXI-5610, PXI-2593, PXIe-2593, PXI-4071, PXI-5154, PXIe-5442, PXI-8433/4). Allow the PXIe-4135 30 minutes to warm up with the PXI chassis fans set to HIGH. 7 GHz Upconverter is new from surplus stock. . . NI PXIe-5442 Module 8. Thanks. The "Source Data" block allows the generation of any. 9375Mhz Symbol Rate: 1200 Symbols per second Deviations: Space = 1800Hz Mark = 1200Hz Modulation Type: CP FFSK We are unable to do this using standard vi. 解决方案. Supported AWG modules include the NI PXI-5421 and NI PXI-5441. 2. ±0. We are following the manual RF application development course manual- Exercise 2. Perspectives. 2. 2. 7 GHz upconverter in a compact, 2-slot 3U PXI module. 0 ???? if the answer is "yes", then HOW TO DO THIS???. NI-DAQmx. By combining the three products into one application, NI lets you generate modulated RF signals at carrier frequencies from 250 kHz to 2. 4 - NI PXI-5421 . 80 dB spurious-free dynamic range. SPECIFICATIONS VIEW LIVE National Instruments PXI-5610 2. Part Number: 189718J-01, 189718L-01, 189718N-01, 189718T-01L, 189718V-01L, 188564M-01L, 189718R-01L, 188564L-01L. I have to develop the DSB-ASK and SSB-ASK modulation schemes. PXI-5610 PXI-5600 PXIE-6259 PXIe-6363 PCI-6284 PXI-1042Q PCI-MXI-2 PXI-1042Q PXI-8106 PXI-6542 PXI-5404 PXI-8331 PXIe. Two Semi-Flexible SMA (m)-to-SMB Cables, Part Number 190846B-01 4. Tektronix is the nation's leading provider of multi-brand calibration services. lib (and in the instrument I/O palette) are for the transceiver and the preamplifier. The PXI-5610 features a wide real-time bandwidth and a highly stable timebase, accurate to within ±50 ppb. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator; Hi, Does anyone have NI PXI-5610 Up-Converter Specification?1. The PXIe‑4610 generates the lowest noise possible while maximizing the power from a single PXI Express slot. Millennium Tower, Etage 41 Handelskai 94-96 . Driver: niRFSG Supported Models: NI PXI-5610, NI PXI-5650, NI PXI-5651, NI PXI-5652 NI PXI-5670, NI PXI-5671, NI PXIe-5611, NI PXIe-5644R NI PXIe-5645R, NI PXIe-5646R, NI PXIe-5650, NI PXIe-5651 NI PXIe-5652, NI PXIe-5653, NI PXIe-5654 NI. National Instruments PXI-2586 10 Channel. . Are there any users currently using any of the newer Agilent ESG Family Generators, in particular an E4428C, with the CalExec procedure for PXI-5610 instead of the E4422B or E4433B? I can see in the Programming Manual for the E4428C that the unit is SCPI command compatible (or partially compatible) with the E44xxB series of generators. Some of these signal processing operations include FIR and CIC interpolation filters, digtal prefilter gain. hwdb | 1987 +++++- hwdb/20-usb-vendor-model. This software installation provides support for customers using RF signal generator or vector signal transceiver hardware, as specified in the section. 01-04-2012 01:37 PM. We have not had any issues with any of the modules with the exception of the PXI-5610 module. I also have been able to drive the output to +27 dBm in a bursted application without errors. Manufacturer. NI PXIe-5672 Specifications RF Vector Signal Generator This document lists specifications for the NI PXIe-5672 (NI 5672) RF vector signal generator. MODULE ASSEMBLY, NI PXI-5610 (ROHS) Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF KC, EMC: PDF Product Support Resources. The 1862 Pacific Northwest smallpox epidemic was a smallpox outbreak that started in Victoria on Vancouver Island and spread among the indigenous. Hi, I have NI PXI 5600 on PXI 1045 chasis along with PXI-5620,PXI-5610,PXI-5421,PXI-4461(from left to right in the pic). Find complete product documentation to learn how to get started and use the product. Any idea why my vi won't return the two actu. pxi-6040e pxie-5673e pxi-5600 pxi-7853r pxie-5645r pxie-4480 pci. The. 确认您使用的NI PXI平台服务 (NI PXI Platform Services)驱动版本是否支持您的 操作系统和LabVIEW Real-Time模块 以及 PXI / PXIe机箱和控制器 。. Refer to thePXIe, 43 MHz Bandwidth, 1-Channel, 16-Bit Onboard Signal Processing, PXI Waveform Generator. To program your device, use the NI-RFSG instrument driver or NI-RFSG Soft Front Panel. Hi, I'm using the DAQmx system and device property nodes to get the logical name of two PXI card, PXI-5441 and PXI-5610. 1 in. Minimum or maximum specifications are guaranteed under the followingI need to create an RF signal using the PXI-5610 & 5421 with the following characteristics: 1. By default, RFSG uses the Divide Down clock which delivers slightly better performance (especially phase noise) vs. It takes in a single-ended IF signal and performs RF upconversion to frequencies up to 2. 3. AI Homework Help. 2 | ni. NATIONAL INSTRUMENTS PXI-2593 500MHz Multiplexer Matrix. Calibration Executive will check and adjust all the parameters of the PXI-5600 and PXI-5610 that are able to be adjusted and that can move over time. The GPS Signal is generated by Averna NAVASIM (NAVigation Advanced SIMulator). The PXI-5610 features a wide, real-time bandwidth and a highly stable timebase. 2. Fax: +49 711 80670-555. The PXIe-5110 oscilloscope has two channels that sample up to 1 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. LabVIEW Help Contains LabVIEW programming concepts and reference. However, with the same setups as were working previously and the examples every time I now receive the following errorThis document explains how to install, configure, and test the NI PXI-5671 (NI 5671). If more bandwidth is needed, consider upgrading to PXIe. PXI & VXI Boards & Modules; National Instruments Ni Pxi-5610 2. The NI 5671 is a 2. 28 shipping. The end user data rate has been shown to be in excess of 5Mbps. eeProductCenter Senior Tech. I am currently working with the calibration executive software version 3. Find complete product documentation to learn how to get started and use the product. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. Quick Start Guide Installation Guide Specifications Documentation Guide NI PXI 5670 Getting Started Guide National Instruments RFSG rf vector signal generator VSG high frequency RF 376026 326026 5610 5421 Technical Communications 376026b ni support hiq manuals ||| GETTING STARTED GUIDE NI PXI 5670 2. 02-27-2012 06:10 AM. 7 GHz RF Vector Signal. . . According to documentation, I should be able to use RFmx or NI-RFSA with NI-RFSG drivers to use this 关闭计算机电源,然后关闭机箱电源。. vi. Read Me First: Safety and ElectromagneticContact. Any hints to resolve this. consists of two components – the NI PXI-5610 2. NI-VISA. The hardware (which includes the PXI-5610 and PXI-5421) are installed on a NI PXI-1045 Chassis with NI-DAQmx and Measurement and Automation Studio 7. PXI & VXI Boards & Modules, National Instruments Broadcast Measurement, National Instruments Data Acquisition Modules,pxi-5610 pci-6031e crio-9081 pxi-5154 ni5791 pxi-1062q pxi-6120 pxi-1042q pxi-4472 pxie-4163 pxi-2532b usb-6356 pxi-7831r pxi-4472b pxie-5646r pxi-7853r pxie-5644r pxi-1000b pxie-7976r pxie-5646r pxie-8135 ni4472 scxi-1129 pxi-5154 pxi-6289 pxie-2569 pxi-1042 pxi-8196 pxi-7350. 7 GHz RF Vector Signal Generators This document lists specifications for the NI PXI-5670/5671 (NI 5670/5671) RF vector signal generators. 04-06-2014 05:59 PM. Description. Manuals. WORLDWIDE SHIPPING. . 7GHz RF Up Converter from National-Instruments Reference: PXI-5610 is available for purchase, calibration and repair. During the adjustment phase, after about 20 minutes the PXI-5610 adjustment stops and Cal-Exec produces the following message: Adjust_NI 5610_TempCo_Main. We are currently not members of Dash7 alliance. The NI 5610 offers 20 MHz real-time bandwidth and an on-board 10 MHz highly stable, low phase-noise oven-controlled crystal oscillator (OCXO) reference clock that can be software-configured to drive the PXI 10 MHz backplane clock only when the NI 5610 is installed in Slot 2 of a PXI chassis. dll in my system32, but there is no document in ni. Products. PXI-5610: √ — PXIe-5611: √. You can program the voltage setpoint and current. This file contains installation instructions and compatibility information for NI-RFSG. . The PXI-5610 RF Upconverter is PXI1Slot5 inside the MAX Return to Home PageHowever I neglected to mention that I am also using the PXIe-5442 with the PXIe-5610 (upconverter) to form a PXIe-5672 (rf vector signal generator). 如果您使用的是MXI-Express x1电缆,请确保机械“ D. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. 7 GHz. Frequency Devices VM8PF-8-D828 Programmable VME Filter Board. 1,200 ns, typical Overload protection on RF output Maximum reverse RF power. Attach is the RF. 2. This document explains how to install, configure, and test the NI PXI-5671 (NI 5671). The PXIe‑4610 offers an easy to use alternative to. Total views 1. 5 and earlier, the MAX test panel supported the NI PXI-5610 with an external AWG module. During the adjustment phase, after about 20 minutes the PXI-5610 adjustment stops and Cal-Exec produces the following message: Adjust_NI 5610_TempCo_Main. 7 GHz Upconverter in a 2-slot, 3U PXI module. 7 GHz, 20 MHz bandwidth digital upconverter, which helps reduce waveform download and time for the signal generation. To reduce this deviation, an external 10 MHz clock source can be introduced into the PXI. NOTE TO USERS Maintain Forced-Air Cooling Inadequate air circulation can cause the temperature inside a PXI, PXI Express, or PC chassis/case to rise above the maximum recommended operating temperature for your device, potentially causing thermal shutdown or damage to the device. NI PXI-5610. Removed the PXI 6653, changed PXI-5610 PXI-5421 back to original positions. PXI-5610 Product Certifications. These three module don't work now. Part Number: 189590C-01, 189718E-01 . NI PXI-5610 2. The selected samples will be 3. The PXIe‑5442 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms, standard functions including sine, square, triangle, and ramp, as well as signals that require onboard signal processing. With a national network of resources, a robust quality program and broad capabilities, we offer standard and custom solutions to deliver fast, accurate calibration when and how it's needed. com. 9. I dont get where the problem is. The PXI‑5441 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms, standard functions including sine, square, triangle, and ramp, as well as signals that require onboard signal processing. これは、マルチスロットシャーシにコントローラと計測器を組み合わせたテストおよび計測用プラットフォームです。. Expert Help. NI-RFSG is an NI instrument driver that you can use to configure and operate the device hardware, perform waveform programming and generation, and perform basic. As RF modules I have the transceiver PXIe-5641R, a downconverter (PXI-5600), an upconverter (PXI-5610) and a preamplifier (PXI-5690). High-stability oven-controlled crystal oscillator (OCXO) timebase. Fixed an issue where some PXI/PXIe-5650/5651/5652 devices fail calibration verification after calibration adjustment. 1 We have made the following external connection in our chassis as per the man. The RF output can be set from. PXI-5610 Specification. I got the downconverted signal but the center frequency signal is 10 MHz which i expect 20 MHz. Feature Usage. Manuals. 7 GHz RF upconverter [14] and the NI PXI-5421 arbitrary waveform generator [14]. Hello, We have an NI PXIe-1065 chassis with a -PXI 5610 and PXI 5442-AWG together (VSG) and -PXI 5600 and PXI 5142-Digitizer together (VSA). ±0. Provides support for NI data acquisition and signal conditioning devices. 7 GHz PXI RF Signal Upconverter—The PXI-5610 frequency-translates IF input signals to the desired RF frequency. A valid service agreement may be required. Because of the flexible hardware and software, PXI-5661. 首先,确保正在操作的用户Windows账号已经被添加到了Windows管理员群组中. 2. Fixed an issue where the PXIe-5820/5840 trigger alignment was imprecise when using the PXI trigger lines. PXIe, 43 MHz Bandwidth, 1-Channel, 16-Bit Onboard Signal Processing, PXI Waveform Generator. PXI. Home Support Documentation Dimensional Drawings PXI-5610 Dimensional Drawings PXI-5610 Dimensional Drawings This page provides dimensional drawings for the PXI-5610. Letter of Volatility PXI-5670 September 2017 Notice: This document is subject to change without notice. pdf file (17 Aug 2023) Manufacturer: National Instruments; Category of Device: Test Equipment; Document: PXI-5671 Getting Started Manual, File Type: PDF; Updated: 17-08-2023; Count of Pages: 24;PXI-1042 Chassis; PXI-8106 Chassis; PXI- 5610 Up converter; PXI-5441 AWG ; PXI-5600 Down Converter ; PXI-5142 Digitizer; 0 Kudos Contributors TiffanyFogarty. 美国NI PXI-5610 输入输出模块 停产备件. Hello, I am currently trying to develop an application that uses the PXI-5441 and PXI-5610 to stream I16 IQ files and there are a couple questions that I've thought of while programming. I have PXI 5600 and PXI 5620 as RFSA and PXI 5610 and PXI 5142 as RFSG on PXI 1045 chasis along with an embedded P-4 processor which will perform the. but after I added new device(PXI 6653) into slot 2, moved PXI-5610 to slot 3,4 and PXI-5421 to slot 5. The amplitude accuracy is degraded, and I suspect spurious output is quite high. How do I replicate this using NI-RFSG? I have a 5672 (PXI-5610 & PXIe-5442) or 5673E (PXIe-5450, PXIe-5611, & PXIe-5652) vector signal generator that I can use. Stock # 89258-1 . See all Driver Software Downloads. 5G and 6G Technology. Open a service request. The NI 5670 comprises the following devices: • NI PXI-5610 (NI 5610) RF upconverter modulePXI-5122EX Data acquisition card, NI, PXI-5122EX Data acquisition card Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. 1. Languages English. Adjustment NI 4110 NI 4130 NI 4132 Verification Adjustment NI 5600 *NI 5601 NI 5610 *NI 5611 NI PXI 5650 191967H-01 and earlier NI PXI-5651 191967H-02 and earlier NI PXI-5652 191967H-03 and e. エンジニアはNI PXIを使用して、検証と製造テストのための高性能な複合測定システムを構築. PXI-5610: √ — I/Q Modulator. PXIe, 6 GHz PXI Vector Network Analyzer—The PXIe‑5630 is a 2‑port vector network analyzer (VNA) for PXI Express that you can use for vector measurements of transmission and reflection (T/R) coefficients, also referred to as S11 and S21. 750 ns, typical 2 NI 5610 upconverter module. It is installed in a PXI chassis and uses a PCI Express‑to‑PCI bridge to interface with an installed PCI‑8360 through a copper, x1 MXI‑Express cable. National Instruments. 0 Kudos. I configure the divided sample clock to output on PFI0 of the PXIe-5442 device. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. 1 We have made the following external connection in our chassis as per the man. National Instruments PXI-5610 (778737-01) used. The PXI‑5441 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms, standard functions including sine, square, triangle, and ramp, as well as signals that require onboard signal processing. PXI-5610 & PXI-5441. 7 GHz Upconverter is used and in excellent condition. com Board Assembly Part Number(s) Part Number Description 189718X-0xL including all letter revisions NI PXI-5610 Manufacturer: National Instruments. The NI 5670 comprises the following devices: • NI PXI-5610 (NI 5610) RF upconverter modulePXIe, 100 MHz, 1 GS/s, 8-Bit PXI Oscilloscope. Hi Marcos, I am having similar issues with the PXI-4070. lib (and in the instrument I/O palette) are for the transceiver and the preamplifier. 7 GHz RF vector signal generator (VSG) with quadrature digital upconversion. The NI 5670 comprises the following devices: • NI PXI-5610 (NI 5610) RF upconverter module Sanitization: Per NIST Special Publication 800-88 Revision 1, “sanitization” is a process to render access to “Target Data” on the media infeasible for a given level of effort. Rohde & Schwarz SMU200A 100kHz-6GHz Vector Signal Generator w/ Options. For the AmplitudeAccuracy_Super10MHz it has me manually input two measurements. Information about the network interfaces CANcaseXL, CANcardXL, CANcardXLe, CANboardXL, CANboardXL PCIe, CANboardXL pxi, VN5610A, and VN5640. General. Volatile Memory . 7 GHz, PXI RF Signal Upconverter. 2. 2. I have the NI RFSG and NI FGEN drivers installe. name_mapping – Optional mapping from default (“raw”) channel names to custom aliases. 8. About this product. $1,279. By programmatically configuring the trigger routing modules on the chassis backplane, you can route triggers between devices with ease. SOLA. Two replications of the NI 5610 onboard 10 MHz reference clock. 若使用此方式,NI对PXIe控制器的任何故障概不负责。. 7 GHz. 7 GHz Upconverter This National Instruments PXI-5610 2. The PXI-5610 features a wide, real-time bandwidth and a highly stable timebase. For a similar experience to the NI 5670 Vector Signal Generator that you are already using (5610 and 5421), you would need a PXI-5142 digitizer to link with the 5600, in order to make an NI 5661 VSA with Digital Downconversion. A PXIe. Provides support for Ethernet,. I know that when using the RFSG drivers the IQ rate must be (100MS/s)/n discrete values with the highest "n" bei. 7 GHz PXI RF Signal Upconverter —The PXI-5610 frequency-translates IF input signals to the desired RF frequency. Also, I noticed that the sh. I have tried a lot: 1. . For example: 1. pxi-6040e pxie-5673e pxi-5600 pxi-7853r pxie-5645r pxie-4480 pci. Any suggestions well be appreciated. Because PXI Express is compatible with all existing PXI modules, engineers also can use the new NI PXIe-5442 module with the NI PXI-5610 2. 2. (12 In Stock)”. 5. University of New South Wales. CONNECTOR ROHS exidrp NI PXI-5441, WAVEFORM GENERATOR, 512MB WITH LVDS, EHM CONNECTOR ROHS exidrp . This is a hybrid-slot-compatible PXI module that can be used in both PXI Express hybrid slots and standard PXI slots. Solved: Hi, I using a PXIe-5442 Arbitary Waveform Generator and a PXI-5610 RF Upconverter. NI-VISA. For further questions or for a personal consultation please contact our technical sales department: Phone: +49 711 80670-500. are not included with this equipment unless listed in the above stock item description. Refer to the. NI PXIe-5672 Specifications 6 ni. The NI 5671 ships with the NI-RFSG instrument driver, which you use to program the device. For further questions or for a personal consultation please contact our technical sales department: Phone: +49 711 80670-500. ; PXI-5441: 8. 127,805. 7 GHz upconverter in a compact, 2-slot 3U PXI module. The PXI-5610 features a wide, real-time bandwidth and a highly stable timebase.